Part Number Hot Search : 
LA503 100LVEL 5SERI 2N2894A GBJ10A04 3T200 HD74H MC34004P
Product Description
Full Text Search
 

To Download TS-3000-224 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification ts-3000-112 ts-3000 -124 ts-3000 -148 ts-3000 -212 ts-3000 -224 ts-3000 -248 150a 21 ~ 30vdc 90% 75a 42 ~ 60vdc 91% 150a 21 ~ 30vdc 91% 75a 42 ~ 60vdc 92% model ac voltage maximum output power waveform output frequency ac regulation (typ.) voltage range (typ.) note.1 efficiency (typ.) note.2 dc current (typ.) note.5 input input battery output environment fuse safety & emc bat. low alarm bat. low shutdown over temperature output short bat. polarity gfci proctection circuit breaker protection protection true sine wave (thd<3%) at rated input voltage 300a 10.5 ~ 15vdc 89% 80a*5 40a*5 30a*3 30a*3 40a*5 3% 10.5 ~ 15vdc 88% 300a 80a*5 105 5 protection type : shut down o/p voltage, re-power on to recover ; by internal rth3 detect on heatsink of power transistor protection type : shut down o/p voltage, re-power on to recover 95 5 95 5 90 5 85 5 85 5 by internal fuse open optional (only type f) ac output receptacle : 15a none emi conduction&radiation ems immunity compliance to fcc class a none working temp. note.3 working humidity storage temp., humidity safety standards 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o ul458 (only for "gfci" receptacle-type f ) en60950-1 compliance to en61000-4-2,3,8 env50204 compliance to en55022 class a, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) power on-off switch standby saving mode can be selectable front panel indicator for operation status thermostatically controlled cooling fan protections: bat. low alarm / bat. low shutdown / over voltage / over temp. / output short / input polarity reverse / overload application : home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. optional monitoring software 3 years warranty high surge power up to 6000w high efficiency up to 92% rated power (typ.) 3000w 3000w 3000w 3000w 3000w 3000w over load (typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover withstand voltage bat i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes features : others packing 11.9kg; 1pcs/13kg/1.98cuft dimension 466.8*283.5*100mm (l*w*h) note 1.efficiency is tested by 2100w, linear load at 13v, 26v, 52v input voltage.2.output derating capacity referenced by curve 1. 3.dc current is tested by 3000w, linear load at 12v, 24v, 48v input voltage. 4.all parameters not specified above are measured at rated load, 25 of ambient temperature. 5.the tolerance of each voltage value by models is:112/212 0.5v;124/224 1v;148/248 2v 200 / 220 / 230 / 240vac selectable by setting button 100 / 110 / 115 / 120vac selectable by setting button 3450w for 180 sec. / 4500w for 10 sec. / surge power 6000w for 30 cycles 11.3 4 % 22.5 4 % 45 4 % 45 4 % 22.5 4 % 10.5 4 % 21 4 % 42 4 % 42 4 % 21 4 % 11.3 4% 10.5 4 % 3000w true sine wave dc-ac power inverter t s - 3 0 0 0 s e r i e s file name:ts-3000-spec 2009-04-09 50 0.1hz 50/60hz selectable by setting button s.w 60 0.1hz 50/60hz selectable by setting button s.w front panel indicator saving mode (typ.) load 5w will be changed to standby mode battery voltage level, output load level, saving mode, fault and operat ion status 24v 48v 24v 48v bat. voltage 12v 12v no load dissipation (typ.) 10w @ standby saving mode off mode draw current 1ma battery types open & sealed lead acid control wiring rj11 -rs232 (option) lvd none none e 13
type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci (expect for 48v input) ac output receptacle (optional) e 13 on bat low saving setting remote port inverter load 100 battery 0 100 0 c i r c u i t b r e a k e r p r e s s t o r e s e t ac output ac intput ac output ac output ac intput ac output on bat low saving setting remote port inverter load 100 battery 0 100 0 c i r c u i t b r e a k e r p r e s s t o r e s e t on off on off 31.29 31.29 13 13 type-a type-b chassis chassis ground ground cat.no.(1gg1hs-212) cat.no.(1gg1hs-212) wire range(10-4 awg str wire range(10-4 awg str cu soldered wires) cu soldered wires) torque (17.7-26.5 in lb) torque (17.7-26.5 in lb) 122.44 161.84 100 31.6 direction air flow direction air flow 273 34 12 283.5 reverse polarity will damage the unit. neg pos 286.2 90.3 466.8 46 7 7.5 ac output fg nc l nc n 3000w true sine wave dc-ac power inverter t s - 3 0 0 0 s e r i e s a :type a outlet b :type b outlet c :type c outlet d :type d outlet e :type e outlet f :type f outlet ts:true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:3000w ts 3000 112 a e e 13 13 file name:ts-3000-spec 2010-04-09 curve 1 ambient temperature ( ) 0 10 20 30 40 50 60 70 20 40 60 80 100 load (%) unit:mm mechanical specification derating curve


▲Up To Search▲   

 
Price & Availability of TS-3000-224

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X